Nylon Cable Glands & Locknuts
Cablecraft's nylon cable gland range covers the full run of sizes used across UK electrical installations, from M12 cable gland up to M63, plus PG-thread sizes from PG7 through to PG48 for legacy and imported enclosures. Also known as polyamide cable glands, they're the standard choice for control panels, consumer units, and light-duty enclosure work, valued for being lightweight, impact-resistant, and quicker to install than metal alternatives.
Alongside the glands themselves, Cablecraft stocks matching cable gland locknuts, sealing washers and grommets, as well as ready-packed nylon cable gland kits covering the common M16–M32 range in one case - useful for contractors working across multiple sites, or consumer unit installations that call for several sizes on one job.
Nylon Cable Gland Ranges stocked by Cablecraft:
Cablecraft stocks a range of nylon cable glands for secure, watertight cable entry across general industrial, panel-building, and rail applications.
Standard Nylon Glands & Locknuts - Polyamide 6; IP68 to 5 Bar; -20°C to +100°C (intermittent to +150°C).
Nylon Glands & Locknuts, PG Thread - Polyamide 6; IP68 to 5 Bar; -20°C to +100°C (intermittent to +150°C).
Smart Fit Glands - Nylon PA6; IP68 to 5 Bar; -20°C to +100°C.
Nylon Cable Gland Kits - Polyamide 6 (glands), PA 6 GF 30 (locknuts); IP68 to 5 Bar; -20°C to +100°C (glands); -20°C to +100°C permanent / -30°C to +150°C intermittent (locknuts).
FAQS
Cable glands are waterproof when they carry an IP68 rating, and are correctly matched to the cable diameter, sealed at the enclosure entry point, and installed to specification. Cablecraft's nylon cable gland ranges, including the standard and PG-thread ranges, and the Smart Fit range, carry an IP68 rating to 5 Bar.
IP68 breaks down as two separate protections: the 6 means dust-tight, with no ingress of dust at all; the 8 means protected against prolonged immersion under pressure, to a depth and duration set by the manufacturer's test conditions. Both ratings apply to the gland's cable-entry seal (the neoprene or chloroprene ring around the cable) and body, not automatically to every point in the installation.
Note on thread sealing: Cablecraft's nylon glands have no entry thread seal as standard. The IP68 rating covers the seal around the cable itself, but without a seal at the thread, where the gland body meets the enclosure, that same IP rating isn't carried through to the enclosure entry point. A rubber sealing washer fitted at the thread closes this gap and should be specified alongside the gland wherever a fully sealed IP68 installation is required, rather than assumed to be included.
Waterproofing in practice depends on:
-
The gland's IP rating - IP68 is the standard for full submersion resistance; lower ratings (e.g. IP54, IP65) offer low-pressure water jets protection or spray protection only
-
A sealing washer at the thread - required to maintain the IP68 rating at the enclosure entry point, since Cablecraft's nylon glands don't include thread sealing as standard
-
Correct cable diameter match - the sealing ring only achieves a watertight seal within its stated clamping range; too loose or too tight compromises it
-
Correct installation - the sealing nut must be tightened to a spanner-tight seal; under-tightening won't achieve the rated IP class even on a correctly specified part
Installation depends on whether the gland is a threaded (locknut) type or a push-fit type.
Threaded nylon glands (standard and PG-thread ranges):
-
Select the correct gland size for the cable's outer diameter, checking it falls within the gland's stated clamping range
-
Fit a rubber sealing washer onto the gland thread, against the enclosure wall - this is required to carry the IP68 rating through to the enclosure entry point, since these glands have no thread seal as standard
-
Feed the cable through the gland body and its sealing ring
-
Insert the gland body through the enclosure's pre-drilled entry hole, with the washer seated between the gland and the enclosure wall
-
Fit the locknut on the inside of the enclosure and hand-tighten
-
Tighten the sealing nut with a spanner to achieve a spanner-tight seal - this compresses the sealing ring against the cable
-
Check that the cable is seated centrally in the gland, with no visible gap in the sealing ring or the thread washer
Push-fit glands (Smart Fit):
-
Confirm the enclosure wall thickness falls within the gland's compatible range
-
Push the gland directly into the enclosure entry point - no locknut is required
-
Insert the cable through the gland
-
To remove or reposition, use the gland's separate adaptor tool rather than pulling the gland free
Without step 2 on the threaded sequence, the gland is dust-tight and cable-sealed but not sealed at the thread - the installation won't hold its IP68 rating at that entry point even though the part itself is correctly rated.