To help you select the best product for your specific needs, our team of product experts at Cablecraft, with 35+ years of collective experience, has put together this guide. We divided recommended products based on environment, task, and conditions. You can use the cable gland selection table for quick reference.



Indoor Mechanical Applications (Armoured Cables)

Designed for internal installations where mechanical cable retention is the primary requirement.

 

Environment: Indoor electrical enclosures, junction boxes, isolators, and lighting installations.

Conditions: Exposure to solid foreign objects.

Technical Task: Seal cable entry for armoured cables while maintaining mechanical strength and providing strain relief. It ensures mechanical cable retention and electrical continuity via armour wire termination.

Recommended Product: BW Industrial Type indoor extruded brass cable gland.

Metric Sizes: M20s to M90.

Compliance: BS 6121 Part 1:2005.

Ingress Protection: IP2X rating.

Technical Notes: Supplied in packs with locknut, earth tag, and shroud. Operating temperature range: -20°C to 90°C.

Indoor/Outdoor Armoured Cable Solutions (SWA / AWA)

High-protection glands for armoured cables exposed to environmental elements.

 

Environment: Indoor/outdoor electrical enclosures, junction boxes, and lighting installations.

Conditions: Exposure to dust, moisture, and weather requiring ingress protection.

Technical Task: Seal cable entry for armoured SWA / AWA cables. Provides mechanical strength, strain relief, and environmental protection (IP Rating) with electrical continuity through armour wire termination.

Recommended Products:

Compliance: BS EN 62444:2013.

Ingress Protection: IP66 rating.

Technical Notes: Supplied in packs with locknut, earth tag, and shroud. Operating temperature range: -20°C to 90°C.

Non-Armoured Cable Entry Systems

Standard solutions for cables without internal armouring.

 

Environment: Indoor/outdoor electrical enclosures, junction boxes, and lighting installations.

Conditions: Exposure to dust, moisture, and weather requiring ingress protection.

Technical Task: Provide environmental protection (IP Rating), mechanical strength, and strain relief for non-armoured cables.

Recommended Products:

Compliance: BS EN 62444:2013.

Technical Notes: A2 glands include locknut and shroud. For Brass Nickel Plated and Polyamide 6 versions, locknuts are supplied separately. Operating temperature for A2: -20°C to 90°C.

Industrial Machinery & Control Panels (Wire Braided)

Specialised for SY/CY braided cables used in industrial automation.

 

Environment: Electrical control panels, switchgear, and industrial machinery.

Conditions: Exposure to dust, moisture, and weather requiring ingress protection.

Technical Task: Seal cable entry for wire braided armoured control cables (SY/CY) while maintaining mechanical strength and strain relief, IP rating

Recommended Product: CX Industrial Type indoor/outdoor brass cable gland.

Ingress Protection: IP66 rating.

Technical Notes: Supplied in packs with locknut, earth tag, and shroud.

Electromagnetic Compatibility (EMC) Solutions

Shielded glands for sensitive electronic environments.

 

Environment: Telecommunications, Automotive, industrial automation, Defence, and Aerospace.

Conditions: Requirements for Electromagnetic Compatibility (EMC) and protection against dust/moisture.

Technical Task: Maintain EMC compatibility by sealing and shielding against external electromagnetic interference. Creates a secure electrical connection between the cable shield and equipment.

Recommended Product: EMC indoor/outdoor nickel-plated brass cable glands.

Sizes: Metric M12 to M63 and PG7 to PG48.

Compliance: BS EN 62444:2013.

Technical Notes: Glands and locknuts are supplied separately.

Marine and Chemically Aggressive Environments

Corrosion-resistant glands for harsh atmospheres.

 

Environment: Marine, offshore, or chemically aggressive industrial environments.

Conditions: Exposure to corrosive atmospheres, dust, moisture, and weather.

Technical Task: High-level environmental protection and mechanical seal for non-armoured cables.

Recommended Product: Stainless Steel indoor/outdoor cable glands.

Metric Sizes: M12 to M63.

Compliance: BS EN 62444:2013.

Ingress Protection: IP68 rating.

Technical Notes: Glands and locknuts are supplied separately.

Hazardous Area Equipment (Explosive Atmospheres)

Certified glands for potentially explosive industrial locations.

For Non-Armoured Cables:

 

Environment: Indoor/outdoor hazardous industrial locations.

Conditions: Explosive atmospheres (Zone 1, 2, 21, and 22).

Task: Seal cable entry with spark prevention and environmental protection.

Recommended Products:

A2F Dual Certified Hazardous Area Brass: cable glands 

Metric sizes: M20s to M75.

Ingress Protection: IP67 rating.

For Armoured (SWA) and Braided (SY) Cables:

 

Environment: Indoor/outdoor hazardous industrial locations.

Conditions: Explosive atmospheres (Zone 1, 2, 21, and 22).

Task: Maintain mechanical strength and spark prevention for SWA and Braided SY cables.

Recommended Product: E1FW Dual Certified Hazardous Area brass cable glands.

Metric Sizes: M20s to M75.

Ingress Protection: IP67 rating.

Technical Notes: All gland packs are supplied with a locknut, an earth tag, and a shroud. Available in both brass and brass nickel-plated finishes.

One-Piece Cable Gland Solution for SWA, SY and CY Cables

A faster-fit gland option for installers working across multiple common cable types.

 

Environment: Indoor/outdoor electrical enclosures, junction boxes, isolators, lighting installations, control panels, and industrial machinery.

Conditions: Exposure to dust, moisture, and weather requiring ingress protection.

Technical Task: Seal cable entry for SWA armoured cables and SY/CY braided cables while maintaining mechanical strength, strain relief, and environmental protection.

Recommended Product: STORM® One-Piece Cable Gland.

Metric Sizes: M20 to M63.

Compliance: Tested in accordance with BS EN 62444.

Ingress Protection: IP68 rating.

Technical Notes: STORM® glands are designed to offer improved ingress protection and faster fitting compared with conventional armoured cable glands. They are suitable for SWA armoured cables, SY and CY braided cables, require no shroud, and feature a UV-stabilised, zero-halogen body.

The range also includes longer thread lengths compared with standard type glands: 17mm on sizes M20s to M32 and 22mm on sizes M40 to M63.

For quicker installation times, STORM® is also available in STORM Taurus™ packs with EarthingNuts™, or E-STORM™ packs with EarthFix™. Both options provide a more convenient earthing connection method compared with traditional earth tags and locknuts.


Cable Gland Selection Table.

Use This Table to Shop by Task, Environment, or Ingress Protection Rating

ENVIRONMENT CONDITIONS TASK RECOMMENDED PRODUCT NOTES
Indoor electrical enclosures, junction boxes, isolators, lighting installations Exposure to Solid foreign Objects Seal Cable Entry for Armoured Cables Maintaining Mechanical strength, Strain relief to prevent cable damage, Environmental Protection, providing mechanical cable retention and electrical continuity via armour wire termination BW Industrial Type indoor extruded brass cable gland with Metric sizes M20s to M90, Ingress Protection IP2X rating, BS 6121 Part 1:2005 All gland packs supplied with a locknut, earth tag and shroud
Operating temperature -20 to 90 °C
Indoor / Outdoor electrical enclosures, junction boxes, lighting installations Exposure to dust, moisture and weather requiring ingress protection Seal Cable Entry for Armoured SWA / AWA Cables, Maintaining Mechanical strength, strain relief to prevent cable damage, Environmental Protection (IP Rating), providing mechanical cable retention and electrical continuity via armour wire termination CW Industrial Type indoor/outdoor extruded brass cable gland with metric sizes M20s to M90, Ingress Protection IP66 rating, BS EN 62444:2013
E1W Dual Seal Industrial Type indoor/outdoor extruded brass cable gland with metric sizes M20s to M90, Ingress Protection IP66 rating, BS EN 62444:2013
All gland packs supplied with a locknut, earth tag and shroud
Operating temperature -20 to 90 °C
Indoor / Outdoor electrical enclosures, junction boxes, lighting installations Exposure to dust, moisture and weather requiring ingress protection Seal Cable Entry for Non-armoured Cables Maintaining Mechanical strength, strain relief to prevent cable damage, Environmental Protection (IP Rating) A2 Industrial Type indoor/outdoor extruded Brass cable gland with Metric sizes M20s to M90, Ingress Protection IP66, BS EN 62444:2013

Brass Nickel Plated Cable glands in Metric sizes M12 to M63 and PG7 to PG48, ingress protection IP68 rating, BS EN 62444:2013

Polyamide 6 Nylon Cable glands in metric sizes M12 to M63 and PG7 to PG48, Ingress Protection IP68 rating, BS EN 62444:2013
A2 gland supplied with locknut and shroud
Operating temperature -20 to 90C

Brass nickel plated and polyamide 6 nylon glands locknuts supplied separately
Electrical control panels, switchgear and industrial machinery Exposure to dust, moisture and weather requiring ingress protection Seal Cable Entry for Wire braided armoured control cables SY/CY Maintaining Mechanical strength, strain relief to prevent cable damage, Environmental Protection (IP Rating) CX Industrial Type indoor/outdoor brass cable gland with Metric sizes M20s to M75, Ingress Protection IP66 Rating to BS EN 62444:2013 All gland packs supplied with locknut earth tag and shroud
Indoor / Outdoor Telecommunications, Automotive, industrial automation and Défense and Aerospace Protecting against Electromagnetic Compatibility (EMC) Exposure to dust, moisture and weather requiring ingress protection To maintain EMC compatibility by sealing and shielding them from external Electromagnetic interference, creating a secure electrical connection between the cable shield and the equipment, maintaining mechanical strength, strain relief to prevent cable damage, and environmental protection (IP rating) EMC Indoor/outdoor nickel-plated brass cable glands in metric sizes M12 to M63 and PG7 to PG48, ingress protection IP68 rating to BS EN 62444:2013 Glands and Locknuts supplied separately
Marine, offshore or chemically aggressive industrial environments Exposure to Corrosive atmospheres, dust, moisture and weather requiring ingress protection Seal Cable Entry for Non-armoured Cables Maintaining Mechanical strength, strain relief to prevent cable damage, Environmental Protection (IP Rating) Stainless Steel Indoor/outdoor Cable Glands in Metric sizes M12 to M63, ingress protection IP68 rating to BS EN 62444:2013 Glands and Locknuts supplied separately
Indoor/outdoor Hazardous Industrial locations Exposure to explosive atmosphere Seal Cable Entry for Non-armoured Cables Maintaining Mechanical strength, strain relief to prevent cable damage, Environmental Protection (IP Rating), spark prevention in use with Zone 1, Zone 2, Zone 21 and Zone 22 hazardous areas A2F Indoor/outdoor Dual certified hazardous area brass cable glands in Metric sizes M20s to M75 to IP67 Rating

Polyamide Metric Cable Glands in Metric sizes M20s to M63
All gland packs supplied with locknut and shroud available in both brass and brass nickel-plated
Indoor/outdoor Hazardous Industrial locations Exposure to explosive atmosphere Seal Cable Entry for Armoured SWA, Braided SY Cables, Maintaining Mechanical strength, strain relief to prevent cable damage, Environmental Protection (IP Rating), spark prevention in use with Zone 1, Zone 2, Zone 21 and Zone 22 hazardous areas E1FW Indoor / outdoor Dual certified hazardous area brass cable glands in Metric sizes M20s to M75 to IP67 Rating All gland packs supplied with locknut earth tag and shroud available in both brass and brass nickel plated
Indoor/outdoor electrical enclosures, junction boxes, isolators, lighting installations, control panels and industrial machinery Exposure to dust, moisture and weather requiring ingress protection Seal cable entry for SWA armoured cables and SY/CY braided cables, maintaining mechanical strength, strain relief and environmental protection STORM® One-Piece Cable Gland in metric sizes M20 to M63, IP68 rated, tested in accordance with BS EN 62444 No shroud required. Suitable for SWA, SY and CY braided cables. UV stabilised and zero-halogen. Designed for faster fitting compared with conventional armoured cable glands. Also available in STORM Taurus™ packs with EarthingNuts™ and E-STORM™ packs with EarthFix™