Black panel trunking is widely used across a variety of industries and applications worldwide. Whether you are extending an existing installation or meeting a new specification the Betaduct range is likely to meet your needs and provide a perfect solution.
Black Trunking: What Cablecraft Stocks
Cablecraft stocks black trunking across two material ranges: standard PVC and LFH Noryl. They look similar on the outside. Under the surface, they're very different products, built for very different jobs.
Here's what's available, and how to choose.
Black PVC Trunking
Our Betaduct PVC range is available in black (RAL9005) across three slot configurations:
Black PVC Open Slot, the most widely used configuration for control panel wiring, with 12mm fingers and 8mm gaps for easy cable routing and lateral break-out. Available from 37.5 x 25mm up to 100 x 150mm.
Black PVC Closed Slot, solid top construction for increased rigidity and better mechanical protection. Ideal where heavier or stiffer cables are being routed. Matching size range to Open Slot.
Black PVC Narrow Slot, 6mm fingers and 4mm gaps for finer cable management, commonly used where wiring density is high and a neater finish is required. Available from 37.5 x 25mm up to 100 x 100mm.
All black PVC trunking is supplied in 2m lengths, with secure clip-on lids, break points on fingers and base, and the same engineered lid retention geometry as the full Betaduct range.
Specification at a glance:
|
Material |
Rigid PVC 9051 LF |
|
Colour |
Black RAL9005 |
|
Operating Temp |
-5°C to +60°C |
|
Flame Resistance |
UL94 V0 |
|
Dielectric Strength |
15 kV/mm |
|
Volume Resistivity |
1E15 Ohm.cm |
|
Glow Wire Flammability |
+960°C | EN 60695-2-11 |
|
UL Recognised |
UL 1565 | E509564 |
|
CSA Recognised |
CSA-C22.2 No. 18.5 | E509564 |
|
Design Standard |
EN50085-1 & EN50085-2-3 |
A solid, impact-resistant general-purpose trunking. If your project is a standard industrial or commercial control panel with no specific fire safety requirements, this is the right product at the right price.
Black LFH Noryl Trunking
Our Betaduct LFH Noryl range is only available in black (RAL9004). If you see black Noryl trunking on an installation, it's there for a reason.
What Is Noryl, And Why Is It Written into Rail, Marine, and London Underground Specifications?
Noryl is a brand name for a high-performance resin compound, specifically the NH6010B grade used across our Betaduct LFH Noryl range. Like standard halogen-free trunking, it is low smoke and zero halogen (LSOH), meaning it won't release toxic or corrosive gases in a fire.
But Noryl and standard halogen-free are not the same product. They're manufactured from entirely different compounds, and that difference in chemistry is what gives Noryl its edge in the most demanding fire-risk environments. Think of it less as a premium version of halogen-free and more as a distinct category of material that happens to share the LSOH classification.
How Does It Compare?
|
Material |
Operating Temp |
Flame Resistance |
LOI |
|
Standard PVC |
-5°C to +60°C |
UL94 V0 |
— |
|
Halogen-Free (PC/ABS) |
-25°C to +90°C |
UL94 V0 |
32% |
|
LFH Noryl (NH6010B) |
-25°C to +120°C |
UL94 V0 |
33% |
All three achieve UL94 V0 flame resistance, but Noryl's higher operating temperature ceiling and superior flame retardancy give it a clear advantage where fire performance is critical. An LOI (Limiting Oxygen Index) of 33% means it requires a higher oxygen concentration to sustain combustion, in real-world fire conditions, it is significantly harder to ignite and keep burning than either of the alternatives.
Historically, the performance gap between standard halogen-free and Noryl was substantial. Advances in plastic compound technology have narrowed it over time, but Noryl still leads on flame retardancy and thermal stability. In the environments where it's specified, that remaining gap is the entire point.
Full Noryl Black Trunking Specification:
|
Material |
Noryl NH6010B Resin |
|
Colour |
Black RAL9004 |
|
Operating Temp |
-25°C to +120°C |
|
Volume Resistivity |
7.6E+17 Ohm.cm |
|
Dielectric Strength |
34 kV/mm |
|
Flame Resistance |
UL94 V0 |
|
Yield Stress |
64 MPa |
|
LOI |
33% |
|
Glow Wire Flammability |
+960°C | EN 60695-2-11 |
|
M1 Flame Rating |
NF P 92501 |
|
Lateral Flame Spread |
20.0 kW/m² |
|
Smoke Density |
ASTM E662 |
|
Design Standard |
EN50085-1 & EN50085-2-3 |
|
London Underground |
Product Registration No. 1107 |
Where Is Noryl Specified?
Rail and transit. Noryl is widely written into rail specifications where fire safety approvals are closely scrutinised and non-negotiable. Our Betaduct LFH Noryl range holds London Underground Product Registration No. 1107. It's a relatively rare approval to hold, and if you're tendering for London Underground-related work, it removes a significant conversation from the process. As the saying goes in the industry: if it's good enough for London Underground, it's good enough anywhere.
Marine and offshore. The combination of LSOH performance, high operating temperature, and low smoke density makes Noryl well-suited to marine vessel wiring and offshore platform installations, where fire containment and evacuation safety requirements are at their most stringent.
Construction and public buildings. Wherever fire strategy, building regulations, or a project specification calls for high-grade halogen-free containment, Noryl is the product that tends to get written in. Once it appears in a specification, it stays there, contractors don't deviate from named products when their liability is on the line.
Data centres. High-density installations with demanding thermal management and fire safety requirements increasingly call for Noryl-grade material, for exactly the same reasons it performs in the environments above.
The Betaduct LFH Noryl Range
Available in three profiles, all in black, all supplied in 2m lengths:
LFH Noryl Open Slot, the most commonly specified profile. Cables thread in and out easily, with clean break-out points on fingers for routing flexibility. Six sizes available, from 37.5 x 25mm up to 75 x 75mm.
LFH Noryl Closed Slot, solid top construction for greater rigidity, useful where cable weight or stiffness could deform open fingers. Matching size range.
LFH Noryl Solid Wall, no slots, for straight cable runs where lateral break-out isn't needed. Three sizes available.
Why Is Noryl More Expensive?
Two reasons: the compound itself commands a significant premium, and Noryl is manufactured in lower volumes than standard materials, which pushes the per-unit production cost up further. It's not a product you specify unless the project genuinely requires it, and that's by design.
If your installation calls for standard panel wiring in an industrial environment, Betaduct PVC will do the job well and at a fraction of the cost. If you're working in a fire-risk environment with a defined safety specification, Noryl is what gets you compliant and keeps you there.
Other Black Trunking Options
Not every project calls for panel trunking. If you're looking for black cable management solutions beyond control panel applications, Cablecraft also stocks:
Black PVC Trunking Lids, spare lids are available across the Betaduct PVC range, including in black, for replacement or extension of existing installations.
Black Cable Sleeving, for applications where flexible sleeving rather than rigid trunking is the right approach, our range includes black PVC and LSF insulated sleeving, black braided sleeving, and black spiral binding for bundle management.
Black Cable Ties, nylon cable ties in black are stocked across a wide range of sizes, and are the standard choice for outdoor or UV-exposed installations where natural ties would degrade.
Black Heat Shrink Sleeving, available across most of our heat shrink ranges, including general-purpose polyolefin, adhesive-lined dual-wall, and specialist fluoropolymer grades. Black is one of the most stocked colours across the range.